ABSTRACT:
This report presents an assessment of the suitability of ft USA-RG2 hydrocode for simulating the flow in a variable-area shock tunnel. A multi-zone gridding technique is used to model the 1:57-Scale LBS test facility at the U.S. Army Research Laboratory. Computations for various grid
This report presents an assessment of the suitability of ft USA-RG2 hydrocode for simulating the flow in a variable-area shock tunnel. A multi-zone gridding technique is used to model the 1:57-Scale LBS test facility at the U.S. Army Research Laboratory. Computations for various grid
Show More
configurations employing inviscid and viscous solution algorithms and dm turbulence models were executed and the results are compared to experimental dam The need for an adequate mesh density in the grid to obtain a realistic flow simulation and the advantage of solving the full Navier-Stokes equations with added k-e turbulence model for the experiment chosen as a bench mark are demonstrated. Show Less