ABSTRACT:
The Steam Generator Subsystem (SGS) uses molten salt (60% NaN03, 4c:86 KN0:3 by weight) as a heat transfer fluid and storage medium. The SGS is a forced recirculation system employing a separate preheater, evaporator, superheater, reheater and steam drum. Separate superheater, reheater,
The Steam Generator Subsystem (SGS) uses molten salt (60% NaN03, 4c:86 KN0:3 by weight) as a heat transfer fluid and storage medium. The SGS is a forced recirculation system employing a separate preheater, evaporator, superheater, reheater and steam drum. Separate superheater, reheater,
Show More
and evaporator components are mandated by the recirculating system and by the specification of a reheat turbine. A separate preheater results in a more economic utilization of the total heat transfer surface. The heat exchangers are horizontally oriented with both salt and water nozzles arranged to facilitate venting and draining. Show Less