This is the final report of Phase 1 of the Molten Salt Steam Generator Subsystem Research Experiment. This specification defines the requirements for and operating characteristics of a molten salt steam generator subsystem (SGS) for the following applications: Nominal 100-MWe net solar
Show More
central receiver electric generating plant (100-MWe solar stand-alone); Nominal 100-MWe net fossil-fueled electric power generating plant that is 50 percent repowered by a solar central receiver system (50-MWe hybrid). Both SGS designs will be capable of supplying main and reheat steam at 538°C (1000°F) and at a rated pressure of 13.12 MPa gage (1903 lb/in2g) to a nominal 100-M.We turbine-generator. The SGSs defined in this specification shall be designed to be site independent to the greatest extent possible. However, to quantify site-dependent design parameters, Yerington, Nevada, was selected as the site location.