ABSTRACT:
A LaJet concentrator facet, 60 in. in diameter, was tested for imaging quality at the Jet Propulsion Laboratory using two methods: (1) autofocus tests with a point source of light at the facet's radius of curvature and (2) tests with the sun close to the horizon as a distant source. These
A LaJet concentrator facet, 60 in. in diameter, was tested for imaging quality at the Jet Propulsion Laboratory using two methods: (1) autofocus tests with a point source of light at the facet's radius of curvature and (2) tests with the sun close to the horizon as a distant source. These
Show More
tests of the LaJet facet indicate that all of the solar image reflected by an LEC 460 solar concentrator made of like facets should fall within a 9-in. aperture if the outer facets are carefully adjusted. Such a concentrator would have acceptable performance, but complete evaluation must be made with an assembled concentrator. Show Less