COST ANALYSIS OF PACKED BEDS FOR THERMAL-ENERGY STORAGE

by MASSACHUSETTS INSTITUTE OF TECHNOLOGY (LINCOLN LABORATORY),

Technical Report, 1978

Barcode

CSP Unique ID 190682619

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

CAES 11; Report; December 1978.

Language

Library's review

ABSTRACT:
A cost analysis of packed beds for thermal-energy storage (TES) in an adiabatic compressed-air-energy storage system is given. Capital costs based on the conceptual design of a TES unit are estimated and their sensitivity to system parameter variation is studied. Two TES conceptual designs
Show More
were considered for: (a) an excavated cavity, and (b) an abandoned mine. A cost comparison is made between surface-sited and underground TES. A cost model was constructed to study the effect of pebble size, insulation thickness, temperature, storage pressure, storage capacity, and other TES components on the TES capital cost.
Show Less