ABSTRACT:
In Volume 2 of this final report, El Paso Electric Company's Newman Unit I Solar Repowering Program defines specifications of the system and subsystem characteristics, design requirements, and system environmental requirements for solar repowering. This unit has a reheat steam turbine
Show More
rated to produce 82 MWe with a 10. l Pa/5380C (1450 psig/1000 F) main steam conditions and a 2.93 MPa/5380C (410 psig/l000°F) reheat steam conditions. The solar subsystem will be designed to supply steam in sufficient quantity and quality to generate 50 percent of the rated electrical power at the design point of noon summer solstice. It will operate in parallel with the present gas/oil fired boiler.