Evaluation of a Once-Through Heat Recovery Steam Generator Concept

by Arinc Research Corporation,

Technical Report, 1988

Barcode

CSP Unique ID 190683251

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

EPRI AP 5772; Report; April 1988.

Language

Library's review

ABSTRACT:
This report presents the results of a reliability, availability, and maintainability (RAM) evaluation of a once-through concept for a combined-cycle heat recovery steam generator (HRSG). The project included a review of differences in reliability and maintainability characteristics of the
Show More
once-through concept and a typical drum-type HRSG design. A special effort was placed on an investigation of the expected performance of the thin-wall alloy 800 boiler tubing used in the once-through HRSG. An analysis was performed by using the UNIRAM computer modeling methodology to compare the predicted availability of the once-through HRSG design with that of a drum-type system. The results of this project provide a basis for understanding the RAM characteristics of the once-through HRSG concept and identify areas where additional research may be beneficial in evaluating this new design for application within the utility industry.