OPERATING AND MAINTENANCE MANUAL FOR MODULAR INDUSTRIAL SOLAR RETROFIT SYSTEM

by FOSTER WHEELER SOLAR DEVELOPMENT CORPORATION,

Technical Report, 1983

Barcode

CSP Unique ID 190683344

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

FWC FWDC TR 83 14; Report; October 1983.

Language

Library's review

ABSTRACT:
This Modular Industrial Solar Retrofit (MISR) system is designed to be retrofitted to an existing industrial facility. When insolation is sufficient, it will generate saturated steam in a safe and reliable manner with a minimum of operator intervention.

The MISR system utilizes a
Show More
heat-transfer loop to deliver hot, pressurized water from the solar collectors to the heat exchanger (SG-101). The water is then recirculated through the accumulator tank (TK-101) to the collectors via a centrifugal pump (P-101), as illustrated in Figure 1.1. In the heat exchanger (SG-101), feed water from the condenser is converted into saturated steam up to 250 lb/in^2g. The accumulator tank (TK-101) accommodates the thermal expansion of water and ensures that boiling is prevented within the heat-transfer loop. During normal operation the plant is controlled by automatic analog controllers.
Show Less