An Assessment of Heliostat Control System Methods

by Solar Energy Research Institute,

Other authorsJim Pearson, Bing Chen
Technical Report, 1986

Barcode

CSP Unique ID 190684023

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

SERI SP 253 2390 DE86004416; Report; January 1986.

Language

Library's review

ABSTRACT:
This document was prepared by the Solar Energy Research Institute (SERI). The objective of this report is to identify and assess alternative contract and communication subelements for heliostats tha2have the potential to react ~$15/m of heliostat mirror area. The cost goal of $15/m
Show More
compares with the $50/m for communication an1 control at the Solar One facility in Barstow, Calif., and with estimates of about $25/m for second-generation systems. To achieve the cost goal the primary objectives are ( l) to identify and (2) to assess the technical feasibility of alternative approaches to heliostat communication and control systems.
Show Less