ABSTRACT:
A simple formalism is developed for analyzing the optical performance of point focus parabolic radiation concentrators. To account for off-axis aberrations of the parabola, an angular acceptance function is defined as that fraction of a beam of parallel radiation incident on the aperture
A simple formalism is developed for analyzing the optical performance of point focus parabolic radiation concentrators. To account for off-axis aberrations of the parabola, an angular acceptance function is defined as that fraction of a beam of parallel radiation incident on the aperture
Show More
which would reach the receiver if the optics were perfect. The radiation intercepted by the receiver of a real concentrator is obtained as a convolution of angular acceptance function, of optical error distribution, and of angular brightness distribution of the radiation source. Losses resulting from absorption in the reflector or reflection at the receiver are treated by a multiplicative factor pa where p = reflectance of the reflector and a = absorptance of the receiver. For numerical calculations, this method is more accurate and less time-consuming than the ray-tracing method. In many cases, there are acceptable approximations whereby the results can be obtained by reading a graph or evaluating a simple curve fit. Show Less