Link to document:
Status
Electronic Resource
Call number
Publication
SAND Report: SAND80-2526, January 1981.
Collection
Language
Library's review
ABSTRACT:
This report describes a test which measures the heat loss from a centrifugal pump under both insulated and uninsulated conditions. Results showed a 27% reduction in heat loss by insulating the pump and an additional 50% reduction by changing to a pump seal not requiring liquid cooling.
This report describes a test which measures the heat loss from a centrifugal pump under both insulated and uninsulated conditions. Results showed a 27% reduction in heat loss by insulating the pump and an additional 50% reduction by changing to a pump seal not requiring liquid cooling.