Test bed concentrator #1 calorimetry results

by Albuquerque Sandia National Laboratories, NM

Technical Report, 1990

Barcode

CSP Unique ID 190708210

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

SAND Report: SAND89-2840, February 1990.

Language

Library's review

ABSTRACT:
Calorimetry was performed on Sandia National Laboratories' Test Bed Concentrator #1 (TBC-1) during late July and early August 1989. The purpose of the tests was to determine the total power available from the concentrator and the amount of the total power that can be focused through a
Show More
22-cm aperture plate located at the nominal focal point of the dish. The 22-cm aperture corresponds to the diameter of several reflux receivers that are currently under development, fabrication and testing at Sandia. The calorimeter tests will allow the efficiency of the sodium reflux receivers to be calculated. The total power (normalized to 1000 W/m2) available from TBC-1 is 66.4 kW into the 22-cm aperture plate. Within error limits, this power level is the same with or without the aperture plate. The power levels stated are for this time (July 1989) and will probably change as the mirrors further degrade. Since the last calorimetry tests were performed, the mirror facets have degraded significantly, and the results presented here support this effect. Finally, three of
the 220 facets were missing.