Molten salt receiver subsystem research experiment : executive summary

by Livermore Sandia National Laboratories, CA

Technical Report, 1982

Barcode

CSP Unique ID 190708777

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

SAND Report: SAND84-8178, November 1982.

Language

Library's review

ABSTRACT:
This is the Executive Summary for a report which presents the preliminary design of a molten salt receiver subsystem for application to solar thermal central receiver power plants. The design is applicable to a repowered utility electric plant or to a stand-alone plant. The receiver
Show More
subsystem consists of an elevated quad-cavity receiver, a concrete tower to support the receiver, riser and downcomer piping within the tower to transport the salt to and from the thermal storage sub-system, heat absorption panels within the receiver cavities to absorb the incident radiant energy, and the pumps, tanks, piping systems, valves, controls and instrumentation necessary to provide safe and efficient operation of the receiver subsystem. Incident radiant energy is concentrated on the receiver cavity openings by a surround heliostat field. The design is based on a 320 ~1Wt receiver sited at Barstow, California. 1he report provides the design requirements necessary to detail the design of the receiver subsystem, a detailed description of the subsystem components, and the design methods employed to produce the design. A development plan highlights the areas of technical uncertainty along with the required development effort to resolve these uncertainties. Manufacturing processes were developed to establish the fabricability of the heat absorption panels. The cost and schedule from design through start up for the receiver subsystem are also provided. The complete Phase I final report has been published as SAN082-8178.
Show Less
Page: 0.1467 seconds