Midtemperature Solar Systems Test Facility (MSSTF) project test results : phase IVA MSSTF system operation

by Albuquerque Sandia Laboratories, NM

Technical Report, 1978

Barcode

CSP Unique ID 190709016

Status

Electronic Resource

Call number

**Click on MARC view for more information on this report.**

Publication

SAND Report: SAND77-1088, November 1978.

Language

Library's review

ABSTRACT:
This report summarizes the results of 21 months of testing a dispersed power system that converts solar energy to electrical and thermal energy during Phase IVA at the Midtemperature Solar Systems Test Facility (MSSTF), Albuquerque, New Mexico. It presents data showing that the production
Show More
of both electrical and thermal energy from solar energy is technologically feasible. Operational experience with the MSSTF has led to the identification of several design modifications and materials and process improvements that will increase system efficiency. System performance is reported both as measured for the existing system and as predicted for a system incorporating the identified improvements.
Show Less
Page: 0.2525 seconds